MCP Tips for better browsing
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1074/mcp.T100009-MCP200 on October 16, 2001.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
T100009-MCP200v1
1/1/69    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Glossary
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Michels, D. A.
Right arrow Articles by Dovichi, N. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Michels, D. A.
Right arrow Articles by Dovichi, N. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Molecular & Cellular Proteomics 1:69-74, 2002.
© 2002 by The American Society for Biochemistry and Molecular Biology, Inc.


Technology

Fully Automated Two-dimensional Capillary Electrophoresis for High Sensitivity Protein Analysis*

David A. Michels, Shen Hu, Regine M. Schoenherr, Michael J. Eggertson and Norman J. Dovichi{ddagger}

From the Department of Chemistry, University of Washington, Seattle, Washington 98195-1700

We report a system for automated protein analysis. In the system, proteins are labeled with the fluorogenic reagent 3-(2-furoyl)quinoline-2-carboxaldehyde, which reacts with lysine residues and creates a highly fluorescent product. These labeled proteins are analyzed by submicellar capillary electrophoresis at pH 7.5 to perform a first dimension separation. Once the first components migrate from the capillary, a fraction is transferred to a second dimension capillary, where electrophoresis is performed at pH 11.1 to further separate the proteins. Laser-induced fluorescence is used as an ultrasensitive detector of the separated proteins. Successive fractions are transferred from the first dimension capillary to the second dimension capillary for further separation to generate, in serial fashion, a two-dimensional electropherogram. The transfer of fractions is computer-controlled; there is no operator intervention once the sample has been injected. Zeptomoles of labeled proteins are detected, providing exquisite sensitivity.


{ddagger} To whom correspondence should be addressed. Tel.: 206-543-7835; Fax: 206-685-8665; E-mail: dovichi{at}chem.washington.edu.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 All ASBMB Journals   Journal of Biological Chemistry 
 Journal of Lipid Research   ASBMB Today 
Copyright © 2002 by the American Society for Biochemistry and Molecular Biology.